RESISTANCE WELDED HC-49/U
and HC-50/U
ELECTRICAL SPECIFICATIONS
|
Frequency Range |
1.800 to 150.000MHz |
Frequency Tolerance (@25șC) |
±30ppm |
Frequency Stability |
±50ppm |
Standard Operating Conditions |
-10șC to +70șC |
Load Capacitance
(CL) |
18pF Standard, Custom CL, 10pF,
or Series Resonant |
Shunt Capacitance |
7pF Max |
Drive Level |
1mWatt Max |
Aging |
±5ppm /yr. Max |
|
Other tolerances, stabilities
& operating temperature ranges available. Call GED for specific
requirements. |
|
EQUIVALENT SERIES
RESISTANCE (ESR) AND MODE OF OPERATION (MODE) |
HC-49/U and HC-50/U
|
Frequency
Range
(MHZ) |
ESR
W
Max |
Mode |
Frequency
Range
(MHZ) |
ESR
W
Max |
Mode |
1.800 - 1.999 |
800 |
Fundamental |
8.000 - 10.999 |
40 |
Fundamental |
2.000 - 2.399 |
500 |
Fundamental |
11.000 - 14.999 |
30 |
Fundamental |
2.400 - 3.299 |
400 |
Fundamental |
15.000 - 25.000 |
25 |
Fundamental |
3.300 - 3.569 |
140 |
Fundamental |
23.000 - 65.000 |
40 |
3rd Overtone |
3.570 - 3.999 |
100 |
Fundamental |
60.000 - 110.000 |
80 |
5th Overtone |
4.000 - 5.999 |
75 |
Fundamental |
110.000 - 200.000 |
120 |
7th Overtone |
6.000 - 7.999 |
50 |
Fundamental |
|
|
|
MECHANICAL
DIMENSIONS |
HC-50/U |
|
HC-49/U |
|
|